Abstract

A method to design low-pass filters (LPF) having a defected ground structure (DGS) and broadened transmission-line elements is proposed. The previously presented technique for obtaining a three-stage LPF using DGS by Lim et al. is generalized to propose a method that can be applied in design N-pole LPFs for N/spl les/5. As an example, a five-pole LPF having a DGS is designed and measured. Accurate curve-fitting results and the successive design process to determine the required size of the DGS corresponding to the LPF prototype elements are described. The proposed LPF having a DGS, called a DGS-LPF, includes transmission-line elements with very low impedance instead of open stubs in realizing the required shunt capacitance. Therefore, open stubs, teeor cross-junction elements, and high-impedance line sections are not required for the proposed LPF, while they all have been essential in conventional LPFs. Due to the widely broadened transmission-line elements, the size of the DGS-LPF is compact.