2009 · 11 citations · 0 references
EngineeringAutomotive EngineeringSystems EngineeringAir ConditioningElectric Vehicle EngineeringElectric Vehicle TechnologyCharging SystemsFuel Injection SystemsCharge ControlDesign AnalysisFlow AnalysisFlow Performance AnalysisGas Collection SystemsOperability RequirementOperability StudySuppression
Several accumulator designs and gas charge systems are considered in order to suppress POGO within the Ares I vehicle Upper Stage Liquid Ox ygen System. The thermodynamic and flow analysis completed to evaluat e candidate designs are presented and the results are used to evaluat e the ability of each concept to meet the levied suppression requirements. One annular accumulator design meets all suppression requirement s while also providing manufacturability and operability advantages. Of the two proposed charge systems to provide and maintain gas within the accumulator, a passive level control design meets the charge req uirements and maximizes reliability.