Limnology and Oceanography · 1992 · 222 citations · 17 references
Natural SciencesOceanographyPhysicsOcean InstrumentationOpticsRadiation MeasurementAtmospheric CorrectionAtmospheric OpticsInstrument ValidationOptical Ocean SensorsSolar IrradianceSolar RadiationDirect MeasurementIrradiance Uncertainty QuantificationMonte Carlo Instrument SimulationsOptical Absorption CoefficientOptical Sensor CalibrationScatteringScattering Coefficient EstimationSolar Zenith Angle
The study proposes a simple correction model for self‑shading error that relaxes size constraints on in‑water optical radiometers. Self‑shading was quantified by Monte Carlo simulations of the light field with and without the radiometer. The simulations show that self‑shading error depends on instrument size and water absorption, is largely independent of scattering, and can exceed 15–20 % unless the radiometer diameter is limited to ≲ 1/30 a for irradiance and ≲ 1/100 a for upwelling; the proposed correction reduces these limits to ≲ 1/6 a and ≲ 1/30 a, while error remains high at high pigment concentrations or wavelengths above 600 nm.
The self‐shading of in‐water optical radiometers for measuring upwelling ( L u ) and irradiance ( E u ) is estimated from Monte Carlo simulations of the light field in the presence and absence of the instrument. It is found that the error ( ε ) induced by the presence of the radiometer is a function of its size and the absorption coefficient ( a ) of the medium, i.e. when ε 15–20% the error is independent of the scattering coefficient ( b ). Direct measurement of L u or E u with ε ≤ 5% places severe limitations on the instrument size, e.g. in the case of a cylindrical housing and small solar zenith angles (the worst case) the diameter of the instrument must be ≲ 1/30 a for E u and ≲ 1/100 a for L u . A correction method based on a simple model of ε is proposed and it is shown that when used these constraints on the diameter are reduced to 1/6 a and 1/30 a , respectively, for an after‐correction error of 5%. The self‐shading error is estimated across the spectrum as a function of the pigment concentration of case 1 waters, and it is found that it can be large for typical radiometers, especially at high pigment concentrations or wavelengths >600 nm.
17
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
George M. Hale, Marvin R. Querry · Applied Optics · 1973 · 4.4K citations
Analysis of variations in ocean color1
Anclré Morel, Louis Prieur · Limnology and Oceanography · 1977 · 2.5K citations · Full text
Louis Marie Prieur, Shubha Sathyendranath · Limnology and Oceanography · 1981 · 836 citations · Full text