Acta Ophthalmologica · 1994 · 27 citations · 10 references
MedicineOphthalmologySurgeryAnterior SegmentOphthalmic SurgeryRefractive SurgeryCataract SurgeryLens SurgeryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorRefractive Error AssessmentClinical Reliability Of RefractionPosterior Chamber Intraocular LensesPostoperative RefractionPostoperative Refractive PredictabilityPreoperative BiometryRefractionRefractive Cataract Surgery
The study included 188 patients, in which a posterior chamber intraocular lens was implanted after extracapsular cataract extraction. After modifications of the intraocular lens constants (SRK formula and SRK II formula) and correction of the axial length measurements (Colenbrander-Hoffer formula) had been made, the mean differences between the actual postoperative spherical equivalent and that predicted by the three formulas were -0.23D, -0.22D and -0.46D, respectively. More than +/-1.0D deviation from the predicted postoperative refraction occurred in about one-third of the cases. Inter-observed discrepancy regarding the accuracy of the preoperative measurement of the ocular axis length is suggested to be the main cause of unpredicted postoperative refractive errors.
10
Improving the Predictability of Intraocular Lens Power Calculations
Jack T. Holladay, Thomas C. Prager, Richard S. Ruiz et al. · Archives of Ophthalmology · 1986 · 167 citations
Medicine, Ophthalmology, Surgery +17
SRK II formula in the calculation of intraocular lens power.
Mohinder S. Dang, P. Raj · British Journal of Ophthalmology · 1989 · 38 citations · Full text
Medicine, Ophthalmology, Surgery +17