Ulnar Nerve Repair by the Silicone Chamber Technique

Göran Lundborg, Lars B. Dahlin, Nils Danielsen

Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · 1991 · 123 citations · 16 references

Concepts

Abstract

The ulnar nerve of a 21-year old man was repaired at the wrist by a silicone chamber technique 10 days after a traumatic transection. A 3 mm gap was left between the nerve ends inside the chamber. At follow-up three years later, motor and sensory recovery was excellent. At exploration at that time a macroscopically normal nerve was found in the tube.

References

16