PubMed · 1990 · 94 citations · 11 references
MedicineNephrologyNuclear MedicineGenitourinary RadiologyRenal Nuclear MedicineRenal Replacement TherapyGlomerular FiltrationRenal AssessmentRenal Function TestingRenal Function TestsRenal Nuclear ImagingRenal ScintigraphyGlomerular Filtration AssessmentGlomerular Filtration Rate AssessmentGlomerular Filtration Rate MeasurementKidney Function MonitoringQuantitative Renal Scintigraphy
Several commonly used scintigraphic methods of GFR measurement were evaluated. Forty-three adult patients with a wide range of ages and renal function were studied. The two-sample plasma method of Russell and the urinary method of Jackson were the most accurate methods overall. The one-sample plasma method of Russell, the volume of distribution method of Fawdry, and a terminal slope method were less reliable, especially at low (0-60 ml/min) GFRs. The renal uptake method of Gates correlated poorly to the standards at all GFR levels even when corrected for body surface area or blood volume. The Russell two point and Jackson urinary GFR's can be used as complementary techniques and are recommended as primary methods of scintigraphic GFR determination.
11
Split Renal Function Testing Using Tc-99m DTPA
Gary F. Gates · Clinical Nuclear Medicine · 1983 · 199 citations
Individual Renal Plasma Flow Determination in 2 Minutes
J.U. Schlegel, S.A. Hamway · The Journal of Urology · 1976 · 124 citations
Medicine, Nephrology, Urology +16