Journal of Cataract & Refractive Surgery · 2009 · 60 citations · 18 references
MedicineOphthalmologySurgeryOcular DiseaseOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionHyperopia CorrectionLaser In Situ KeratomileusisLaser SurgeryPostoperative Refractive OutcomesRefractive ErrorAstigmatic CorrectionAstigmatic OutcomeFemtosecond Laser Astigmatism CorrectionFemtosecond Laser UsePostoperative Visual AcuityRefractive AstigmatismResidual Refractive Error CorrectionUncorrected Visual Acuity
PURPOSE: To evaluate the visual and refractive outcomes of laser in situ keratomileusis (LASIK) to correct residual refractive error after apodized diffractive multifocal intraocular lens (IOL) implantation. SETTING: University of Texas Southwestern Medical Center, Dallas, Texas, USA. METHODS: This retrospective study reviewed eyes of consecutive patients who had LASIK using the IntraLase FS60 femtosecond laser and Visx Star S4 excimer laser to correct residual refractive error after AcrySof ReSTOR IOL implantation. RESULTS: The review comprised 85 eyes of 59 patients. Thirty-six eyes (42.3%) had myopic correction, 35 (41.2%) had mixed astigmatic correction, and 14 (16.5%) had hyperopic correction; 45 eyes (52.9%) also had neodymium:YAG (Nd:YAG) capsulotomy. Six months after LASIK, 91.8% of eyes had an uncorrected distance visual acuity (UCVA) of 20/25 or better, 92.9% had an uncorrected near visual acuity (UCNVA) of J1 or better, and 85.9% had 20/25 or better UCVA concurrent with J1 or better UCNVA. No eye lost more than 1 line of best spectacle-corrected visual acuity; 2 eyes (2.4%) lost 1 line. Ninety-nine percent of eyes were within +/-1.00 diopter (D) of emmetropia, and 98% of eyes were within +/-1.00 D cylinder. There was no significant difference in postoperative UCVA or UCNVA between the 3 refraction groups (P >.05) or between eyes that had Nd:YAG capsulotomy and those that did not (P >.05). CONCLUSION: Laser in situ keratomileusis for residual ametropia after apodized diffractive multifocal IOL implantation was predictable, effective, and safe.
18
European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular Lens
Thomas Kohnen, David W. Allen, C Boureau et al. · Ophthalmology · 2006 · 281 citations
Medicine, Ophthalmology, Surgery +11
Emma J. Hollick, David J. Spalton, Paul G. Ursell et al. · Journal of Cataract & Refractive Surgery · 1998 · 159 citations
Medicine, Ophthalmology, Surgery +15
Femtosecond Laser versus Mechanical Microkeratome for LASIK
Sanjay V. Patel, Leo J. Maguire, Jay W. McLaren et al. · Ophthalmology · 2007 · 127 citations
Medicine, Ophthalmology, Surgery +12