Application of ${\rm MgB}_{2}$ Wire to Liquid Hydrogen Level Sensor—External-Heating-Type ${\rm MgB}_{2}$ Level Sensor

M. Takeda, Yoshiharu Matsuno, Iwao Kodama, Hiroaki Kumakura, C. Kazama

IEEE Transactions on Applied Superconductivity · 2009 · 20 citations · 3 references

Concepts

Abstract

A superconducting magnesium diboride (MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) level sensor for liquid hydrogen has been timely noted as a new sensor from a viewpoint of the worldwide storage and transport of large quantities of hydrogen. The external-heating-type level sensors (200 and 800 mm long) based on MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> wires are fabricated by an in situ method, and their level-detecting characteristics are studied in comparison with the actual liquid level using the liquid hydrogen experiment facility (LHEF). It becomes evident that an external-heating-type MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> level sensor has a high linearity, a small measurement error, and a good reproducibility even in the pressure range of up to 200 kPaG despite the evaporation loss caused by the heater used.

References

3