MedicineCardiologyPhysiologyClinical CardiologyElectrophysiologyHemodynamic ManagementAtrial FibrillationCardiac CatheterizationCardiac PhysiologyCardiovascular PathophysiologyCardiovascular PhysiologyHemodynamicsAtrial Fibrillation PathophysiologyCardiac Catheterization HemodynamicsCardiac Systolic FunctionLeft Ventricular MechanicsLeft Ventricular PhysiologyLeft Ventricular Systolic FunctionPressure - Volume Relationship
BACKGROUND: The variation in stroke volume and pulse pressure characteristic of atrial fibrillation is usually ascribed to time-dependent ventricular filling, implying a single positive relationship between end-systolic pressure and volume, which defines a single state of myocardial contractility. We tested the hypothesis that contractility also varies. METHODS AND RESULTS: We measured the left ventricular pressure and volume continuously with a conductance catheter with catheter-tip micromanometer introduced retrogradely into the left ventricle. The end-systolic pressure-volume relationship was determined in 6 patients in atrial fibrillation undergoing cardiac catheterization for diagnostic purposes and 4 control patients in sinus rhythm undergoing coronary artery bypass graft surgery. The normal positive relationship between end-systolic pressure and volume was found in the control patients, but no such positive relationship was found in any patient in atrial fibrillation. In the latter, the slopes of the linear regressions were either not significantly different from zero or significantly negative (r values <0.08), both results indicating a change in contractility from beat to beat. Significantly negative relationships were found between end-systolic volume and preceding R-R interval (-0.82<r<-0.24), indicating the presence of mechanical restitution. Significantly positive relationships were found between end-systolic volume and the R-R interval before the preceding R-R interval (0.35<r<0.74), indicating the presence of postextrasystolic potentiation. CONCLUSIONS: Myocardial contractility is constantly changing from beat to beat in atrial fibrillation because of the influence of the force-interval relationships.
25
The use of biplane angiocardiography for the measurement of left ventricular volume in man
Harold T. Dodge, H. Sandler, Donald W. Ballew et al. · American Heart Journal · 1960 · 1.3K citations
Medicine, Cardiology, Radiology +13
Continuous measurement of left ventricular volume in animals and humans by conductance catheter.
Jan Baan, Enno T. van der Velde, Hein G. de Bruin et al. · Circulation · 1984 · 902 citations · Full text
Engineering, Cardiology, Physiology +17
Calcium transients in mammalian ventricular muscle
David G. Allen, Satoshi Kurihara · European Heart Journal · 1980 · 233 citations