Rapid Communications in Mass Spectrometry · 2012 · 25 citations · 14 references
Life SciencesBiochemistryAnalytical ChemistryMass Spectrometric AnalysisProteomicsMass SpectrometryMass Spectrometry-based ProteomicsPeptide AnalysisPeptide IdentificationProtein IdentificationTop-down ProteomicsInstrument CalibrationMass Spectrometry ProteomicsMatrix-assisted Laser Desorption/ionizationPeptide Mass SpectrometryProtein Mass SpectrometryProteomic IdentificationTandem Mass SpectrometryTandem Mass Spectrometry Analysis
RATIONALE: Matrix-assisted laser desorption/ionization (MALDI) time-of-flight-time-of-flight (TOF-TOF) post-source decay (PSD) tandem mass spectrometry (MS/MS) has seen increasing use for analysis of non-digested protein ions for top-down proteomic identification. However, there is no commonly accepted calibrant for this purpose beyond the use of peptide calibrants whose fragment ions span a lower mass-to-charge (m/z) range. METHODS: We have used the PSD-generated fragment ions of disulfide-reduced/alkylated thioredoxin (AlkTrx) for TOF-TOF calibration in reflectron mode for the purpose of PSD-MS/MS analysis. The average m/z values of AlkTrx fragment ions were used for calibration. The quality of the calibration was assessed from the observed fragment ion mass error of MS/MS of the YahO protein from an unfractionated bacterial cell lysate of Escherichia coli O157:H7 as well as from MS/MS of bovine ubiquitin. The fragment ion mass errors of these two analytes were also used to assess instrument calibration using the monoisotopic fragment ions of [Glu(1)]-fibrinopeptide B (GluFib). RESULTS: A general improvement in fragment ion mass accuracy was observed using the AlkTrx calibration compared to the GluFib calibration which resulted in a more significant top-down proteomic identification of these analyte proteins. CONCLUSIONS: Our results suggest that AlkTrx may be useful as a calibrant for MALDI-TOF-TOF-PSD-MS/MS of small and modest-sized protein ions. The uniform fragmentation efficiency of YahO across its sequence suggests that it may be useful as a post-calibration standard to assess PSD-MS/MS instrument performance as well as establishing appropriate top-down proteomic fragment ion tolerances.
14
Clifton K. Fagerquist, Brandon R. Garbus, William G. Miller et al. · Analytical Chemistry · 2010 · 143 citations
Top-Down Proteomics for Rapid Identification of Intact Microorganisms
Plamen A. Demirev, Andrew B. Feldman, Paul J. Kowalski et al. · Analytical Chemistry · 2005 · 136 citations