2009 · 44 citations · 16 references
EngineeringElectrical EngineeringElectric MachinesFault ToleranceMachine DesignElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsMachine WindingsPermanent Magnet MachinesCogging TorqueFault Tolerant OperationFault-tolerant Drive SystemsFractional-slot WindingsMotor Drive ControlMotor Drive SystemsMotor Fault ToleranceMotor Windings
This paper presents a novel five-phase fault tolerant interior permanent magnet (IPM) motor drive with higher performance and reliability for electric vehicles applications. A new machine design along with efficient control strategy is developed for fault tolerant operation of electric drive without severely compromising the drive performance. Fault tolerance is achieved by employing a five phase fractional-slot concentrated windings configuration IPM motor drive, with each phase electrically, magnetically, thermally and physically independent of all the others. The proposed electric drive system presents higher torque density, negligible cogging torque, and about plusmn0.5% torque ripple. Power converter requirements are discussed and control strategies to minimize the impact of machine or converter fault are developed. Besides, all the requirement of a fault tolerant operation, including high phase inductance and negligible mutual coupling between phases are met. Analytical and finite element analysis and comparison case studies are presented.
16
Fault-tolerant permanent magnet machinedrives
B.C. Mecrow, A.G. Jack, J.A. Haylock et al. · IEE Proceedings - Electric Power Applications · 1996 · 372 citations
Engineering, Electrical Engineering, Systems Engineering +17