Comparing Scalpel, Electrocautery and Ultrasonic Dissector Effects: The Impact on Wound Complications and Pro-Inflammatory Cytokine Levels in Wound Fluid from Mastectomy Patients

114

Citations

18

References

2011

Year

Abstract

Ultrasonic dissector decreases operation time by decreasing the amount of bleeding without increasing the seroma incidence. High cytokine levels in drainage fluids from patients operated with elecrocautery indicates that electrocautery induces more tissue damage and acute inflammatory response. Therefore, seroma, due to acute inflammatory response, was seen more frequently in the electrocautery group. Ultrasonic dissector coagulates protein by breaking hydrogen bonds which may close vascular and lymphatic channels more precisely. But, its actual preventive effect on seroma formation might be related to diminished inflammatory response.