IEEE Sensors Journal · 2010 · 44 citations · 7 references
EngineeringElectrical EngineeringElectromagneticsElectromagnetismInstrumentationElectrical MeasurementMagnetic ComponentsHigh-sensitivity MagnetometersMagnetometer InstrumentationMagnetometersPower ConsumptionPower Consumption OptimizationSize
A compact and sensitive three-axial search coil magnetometer has been designed, built, and tested. The magnetometer sensitivity threshold equals 12 pT/Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.5</sup> at 1 Hz, and the magnetometer dimensions are 72 mm × 69 mm × 69 mm. All the magnetometer coils, the electronics, and batteries are accommodated within a single electrostatic shield and a single housing. A close to 2 aspect ratio (30 mm diameter, 58 mm total length) of the search coils provides a very high (~70%) volume utilization factor. Such a small aspect ratio is obtained due to employing 30-mm diameter, 4-mm thick flux concentrators. The magnetometer is optimized for 20 mHz to 7 Hz frequencies and for ultra-low (252 μW) power consumption. The ultra-low-power consumption enables a seven-year continuous operation from the four 1/2AA lithium batteries. The effect of the integration of three orthogonal search coils on the magnetometer sensitivity and accuracy has been investigated.
7
The Search Coil Magnetometer for THEMIS
A. Roux, O. Le Contel, Christophe Coillot et al. · Space Science Reviews · 2008 · 228 citations · Full text
First results of low frequency electromagnetic wave detector of TC-2/Double Star program
Jinbin Cao, Z. X. Liu, Junying Yang et al. · Annales Geophysicae · 2005 · 58 citations · Full text