2008 · 15 citations · 9 references
EngineeringPetroleum EngineeringDrillingDrilling EngineeringOcean InstrumentationCurrent Measurement InstrumentsDrilling HydraulicsDrilling MechanicsMarine RisersRiser SystemsAcoustic Doppler Current ProfilersAcoustic Doppler Current ProfilingMarine Drilling RisersMarine Riser EngineeringRiser Current LoadingRiser MonitoringSurface Current MeasurementSurface Current Response
In September 2004 BP retrieved a Gulf of Mexico drilling riser due to excessive loop currents. Whilst waiting for the currents to diminish an impromptu full scale riser Vortex Induced Vibrations (VIV) test was carried out using the drilling riser standalone monitoring system. A 6-5/8 inch drill pipe was instrumented and deployed under the drilling vessel to a depth of 1,000ft. The drilling vessel drift was varied relative to the loop current to produce a range of current profiles and surface current speeds. Current loading along the length of the drill pipe was measured using the on-board acoustic doppler current profiler (ADCP). The paper describes the test set-up and measured VIV response. It includes observations of cross flow VIV, in-line VIV and additional response at higher frequencies not currently predicted with industry VIV analysis tools.
9
Fatigue Damage From High Mode Number Vortex-Induced Vibration
J. Kim Vandiver, Susan B. Swithenbank, Vivek Jaiswal et al. · 2006 · 73 citations