Annals of Pharmacotherapy · 2008 · 27 citations · 23 references
PharmacyPharmaceuticsPharmacologyDrug DeliveryPharmaceutical FormulationPulmonary Drug DeliveryAerosol TherapyInhalation Dosage FormsInhalation Drug DeliveryPharmaceutical StabilityPhysicochemical CharacterizationStability Of Pharmaceutical FormulationsAerosol Physicochemical PropertiesBudesonide TherapyChemical Stability TestingHigh-performance Liquid ChromatographyHigh-performance Liquid Chromatography AnalysisPhysical Compatibility TestingPhysicochemical CompatibilityPhysicochemical Drug Compatibility
BACKGROUND: Patients with chronic obstructive pulmonary disease (COPD) are often given admixtures of nebulizable drugs to minimize the time of administration in treatment regimens. OBJECTIVE: To evaluate the physicochemical compatibility and aerodynamic characteristics of formoterol fumarate 20 microg/2 mL when mixed or sequentially nebulized with budesonide inhalation suspension 0.5 mg/2 mL, ipratropium bromide 0.5 mg/2.5 mL, cromolyn sodium 20 mg/2 mL, or acetylcysteine 10% (100 mg/mL). METHODS: The admixtures were prepared in triplicate and analyzed for physicochemical compatibility at 0, 15, 30, and 60 minutes after mixing at room temperature. Physical compatibility was determined by visual examination and measurements of pH, osmolality, and turbidity. Chemical stability was evaluated using compendial or in-house-validated high-performance liquid chromatography (HPLC) assay methods. The aerodynamic characteristics of the admixtures or sequentially nebulized drugs were determined from aerosols generated from a Pari LC Plus nebulizer, using an 8-stage cascade impactor followed by HPLC analysis of the deposited drug. RESULTS: The admixtures remained clear, colorless solutions with no precipitation, except for cloudiness observed in the formoterol/budesonide combination due to budesonide suspension. The pH, osmolality, and turbidity for all admixtures were within the initial values (< or = 3%), and there were no significant changes (< or = 2%) in potency of the active components throughout the 1-hour study period. Due to increased drug volume or reconcentration in the nebulizer cup, the respirable fraction/delivered dose increased significantly (p < 0.05) for the mixed or sequentially nebulized drug. However, the fine particle fraction (FPF), mass median aerodynamic diameter, and geometric standard deviation generally remained unchanged for all admixtures, with the exception of FPF for the formoterol/budesonide combination. CONCLUSIONS: Our results indicate that admixtures of formoterol with budesonide, ipratropium, cromolyn, or acetylcysteine are physically and chemically compatible. However, admixing or sequential nebulization significantly increased the amount of drug delivered compared with single drug nebulization. The clinical implications of the in vitro data in patients with COPD have not been determined.
23
Lawrence A. Trissel · Annals of Internal Medicine · 1977 · 581 citations
European Respiratory Society Guidelines on the use of nebulizers
John Dennis, B. Ronan O’Driscoll, Torsten Bauer et al. · European Respiratory Journal · 2001 · 277 citations · Full text
Medication Nebulizer Performance
Dean Hess, Daniel F. Fisher, Purris Williams et al. · CHEST Journal · 1996 · 234 citations
Droplets Produced by Medical Nebulizers
Paul Phipps, B. Pharm, Igor Gonda · CHEST Journal · 1990 · 153 citations