2002 · 35 citations · 2 references
ComputingComputer ScienceOphthalmologyComputer VisionOcular AnatomyOcular ImagingAnatomical Landmark IdentificationImage RegistrationMedical Image FormationRetinal AnatomyRetinal ImagingSpatial RegistrationAnatomical RegistrationAutomated Image RegistrationBlood Vessel MorphologyImage Co-registrationMedical Image RegistrationRegistration Error AnalysisRetinal Image ProcessingVisual Similarity Assessment
Describes a method of registering retinal images automatically. Control points are automatically identified in each image from blood vessel segments extracted from both images. The location of the optic nerve is used check the spatial similarity of control point pairs. The control point pairs are ranked with a similarity assessment that calculates a correlation of image intensity around each control point. Using a model of an idealized registration, the authors calculate the expected scaling factor between the images. Control point pairs that differ from this expected scaling factor are eliminated, with a bias against pairs with a low similarity assessment. Accurate registration is reported in 22 out of 23 image pairs. The registration error is related to the errors from the methods used to extract the vascular tree and to identify the location of the optic nerve.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
2
Michael H. Goldbaum, Valentina L. Kouznetsova, Brad Côté et al. · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1993 · 18 citations