Clinical Chemistry · 2007 · 119 citations · 32 references
EngineeringBioengineeringBiomedical EngineeringAnalytical ChemistryBiosensorsElectroanalytical MethodsElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsImmunoassay AnalysisImmunoassay DevelopmentTumor MarkersCancer Antigen 125Cancer Biomarker ImmunosensorsClinical Diagnostics Using ImmunosensorsElectrochemical ImmunosensorsImmobilizationImmunosensorsMulti-analyte BiomarkersQuantification Of Analytes
BACKGROUND: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator-grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. RESULTS: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 microg/L, 250 microg/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 micro/L, 1.7 microg/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were <7.8% and <9.0%, respectively. The immunosensor arrays were stable for 28 days. CONCLUSIONS: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device.
32
Avidin: A Natural Bridge for Quantum Dot-Antibody Conjugates
Ellen R. Goldman, Eric Balighian, Hedi Mattoussi et al. · Journal of the American Chemical Society · 2002 · 517 citations
Electrochemical Coding for Multiplexed Immunoassays of Proteins
Guodong Liu, Joseph Wang, Jeong‐Hwan Kim et al. · Analytical Chemistry · 2004 · 285 citations