IEEE Transactions on Industrial Electronics · 2006 · 62 citations · 13 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsFault DetectionFault ModelingGenerator OperationMachine WindingsMagnetic Circuit AnalysisSynchronous MachinesExperimental Results InterpretationHarmonic EffectsHarmonicsMachine Fault DiagnosisSpace Harmonics In WindingsSynchronous Machine ModelingWinding Resistance
A synchronous machine internal faults model based on the actual winding arrangement is described in this paper. Based on the winding function approach, the machine inductances are calculated directly from the machine winding distribution, thereby the space harmonics produced by the machine windings are readily taken into account. Moreover, the calculation of the machine inductances is made easier by the use of the machine electrical parameters instead of the geometrical ones. Simulation results for internal faults on a laboratory generator are compared with experimental results to verify the accuracy of the proposed model
13