European Heart Journal · 2010 · 262 citations · 34 references
MedicineCardiologyClinical CardiologyDiagnostic ImagingUltrasoundCardiac AssessmentCardiac ImagingCardiac UltrasonographyCardiac UltrasoundCardiovascular ImagingEchocardiographic Hemodynamic AssessmentEchocardiographic BiomarkersEchocardiographic HemodynamicsEchocardiographic QuantificationEchocardiography-guided TherapyResynchronizationSpeckle Tracking Ultrasonography
AIMS: The Speckle Tracking and Resynchronization (STAR) study used a prospective multi-centre design to test the hypothesis that speckle-tracking echocardiography can predict response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: We studied 132 consecutive CRT patients with class III and IV heart failure, ejection fraction (EF) < or =35%, and QRS > or =120 ms from three international centres. Baseline dyssynchrony was evaluated by four speckle tracking strain methods; radial, circumferential, transverse, and longitudinal (> or =130 ms opposing wall delay for each). Pre-specified outcome variables were EF response and three serious long-term events: death, transplant, or left ventricular assist device. Of 120 patients (91%) with baseline dyssynchrony data, both short-axis radial strain and transverse strain from apical views were associated with favourable EF response 7 +/- 4 months and long-term outcome over 3.5 years (P < 0.01). Radial strain had the highest sensitivity at 86% for predicting EF response with a specificity of 67%. Serious long-term unfavourable events occurred in 20 patients after CRT, and happened three times more frequently in those who lacked baseline radial or transverse dyssynchrony than in patients with dyssynchrony (P < 0.01). Patients who lacked both radial and transverse dyssynchrony had unfavourable clinical events occur in 53%, in contrast to events occurring in 12% if baseline dyssynchrony was present (P < 0.01). Circumferential and longitudinal strains predicted response when dyssynchrony was detected, but failed to identify dyssynchrony in one-third of patients who responded to CRT. CONCLUSION: Dyssynchrony by speckle-tracking echocardiography using radial and transverse strains is associated with EF response and long-term outcome following CRT.
34
Roberto M. Lang, Michelle Bierig, Richard B. Devereux et al. · Journal of the American Society of Echocardiography · 2005 · 11.3K citations
Cardiac Resynchronization in Chronic Heart Failure
William T. Abraham, Westby G. Fisher, Andrew L. Smith et al. · New England Journal of Medicine · 2002 · 4.6K citations · Full text
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
W Illiam T. A Braham, W Estby G. F Isher, L. S Mith et al. · 2002 · 3.8K citations