Movement Disorders · 2003 · 32 citations · 16 references
MedicineNeurologyNuclear MedicineCost-effectiveness AnalysisDiagnostic ImagingDiagnostic Nuclear MedicineBrain ImagingDiagnostic Decision SupportMedical ImagingMedical Technology AssessmentParkinson DiseaseParkinsonian DisordersCost-effectivenessCost-effectiveness Of Diagnostic TestingDecision-tree AnalysisDiagnostic Cost AnalysisDiagnostic Test CostsImaging CostsImaging Test UtilizationSingle-photon Emission Computed Tomography Tracers
As a diagnostic test for patients with suspected Parkinson's disease (PD), single photon emission computed tomography (SPECT) using [(123)I]FP-CIT tracer has better sensitivity but is more expensive than regular clinical examination (CE). Our objective was to evaluate the clinical and economic impacts of different diagnostic strategies involving [(123)I]FP-CIT SPECT. We developed a decision tree model to predict adequate treatment-month equivalents (ATME), costs, and incremental cost-effectiveness ratio (ICER) during a 12-month time horizon in patients with suspected PD referred to a specialized movement disorder outpatient clinic. In our cost- effectiveness analysis, we adopted the perspective of the German health care system and used data from a German prospective health care utilization study (n = 142) and published diagnostic studies. Compared strategies were CE only (EXAM+), SPECT only (SPECT+), SPECT following negative CE (SINGLE+), and SPECT following positive CE (DOUBLE+). Costs of SPECT amounted to euro;789 per investigation. Based on our model, expected costs (and ATME) were euro;946 (52.85 ATME) for EXAM+, euro;1352 (53.40 ATME) for DOUBLE+, euro;1731 (32.82 ATME) for SINGLE+, and euro;2003 (32.96 ATME) for SPECT+; performance of SPECT was induced in 0%, 54%, 56%, and 100% of the patients, respectively. DOUBLE+ was more effective and less expensive than SINGLE+ or SPECT+; thus these two do not offer reasonable choices. The ICER of DOUBLE+ compared to EXAM+ was euro;733 per ATME gained. In sensitivity analyses, the ICER of DOUBLE+ versus EXAM+ ranged from euro;63 to euro;2411 per ATME gained. Whether the diagnostic work-up of patients referred to a specialized movement disorder clinic with a high prevalence of PD should include [(123)I]FP-CIT SPECT depends on patient preferences and the decision maker's willingness to pay for adequate early treatment. SPECT should be used as a confirmatory test before treatment initiation and limited to patients with a positive test result in the clinical examination. These results should be adjusted to the specific setting and individual patient preferences.
16
Margaret M. Hoehn, Melvin D. Yahr · Neurology · 1967 · 12K citations · Full text
What features improve the accuracy of clinical diagnosis in Parkinson's disease
Andrew Hughes, Yoav Ben‐Shlomo, Susan E. Daniel et al. · Neurology · 1992 · 1.3K citations
The accuracy of diagnosis of parkinsonian syndromes in a specialist movement disorder service
Andrew Hughes, Susan E. Daniel, Yoav Ben‐Shlomo et al. · Brain · 2002 · 1.2K citations
Medicine, Neurology, Neurosurgery +12
Milton C. Weinstein, John Hornberger, Magnus Johannesson et al. · Value in Health · 2003 · 1.2K citations · Full text