Veterinary Surgery · 1996 · 20 citations · 6 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsMechanical Behavior Of MaterialsOrthopedic BiomechanicsBone BiomechanicsBone MechanicsFixation BiomechanicsFracture BiomechanicsBone Failure MechanismsBone Fracture BiomechanicsBone Stress DistributionMetacarpal AnatomyPlastic Deformation BehaviorPlastic Stress ConcentrationStiffnessTorsional Stiffness
The torsional monotonic structural material properties of equine metacarpi with or without, either a 5/16 inch or 3/8 inch diameter bicortical lateromedial middiaphyseal hole were assessed to determine the effect of a hole on metacarpal strength. Torsional stiffness was not significantly effected by the presence of a bicortical hole, whereas yield and failure angles, torques and energies of metacarpi with a hole were 51% to 97% of those of intact bones. Significant differences were not apparent for yield and failure mechanical properties between metacarpi with a 5/16 inch diameter hole and metacarpi with a 3/8 inch diameter hole; however, postyield mechanical properties were lower for metacarpi with a 3/8 inch hole. Whereas some metacarpi with a 5/16 inch hole were capable of plastic deformation before failure, metacarpi with a 3/8 inch diameter hole appeared to have sufficient stress concentration to propagate complete fracture on structural yield.
6
The effect of biopsy-hole shape and size on bone strength
CR Clark, C. Morgan, DA Sonstegard et al. · Journal of Bone and Joint Surgery · 1977 · 169 citations
Structural consequences of transcortical holes in long bones loaded in torsion
John A. Hipp, B.C. Edgerton, Kai‐Nan An et al. · Journal of Biomechanics · 1990 · 74 citations