Seminars in Ophthalmology · 2014 · 14 citations · 18 references
Health ProfessionsOphthalmologyOptometryClinical OptometryClinical Vision ScienceOcular ImagingCorneal TopographyIntraocular Pressure MeasurementOcular BiometryAnterior Chamber Depth ChangesAnterior Corneal CurvatureCentral Anterior Chamber DepthCentral Corneal Thickness MeasurementCorneal Curvature MeasurementCorneal DiameterOcular BiometricsPupil Diameter
PURPOSE: To evaluate the effects of the Valsalva Maneuver (VM) on ocular biometry and intraocular pressure (IOP). METHODS: This prospective observational study included 55 eyes of 55 healthy volunteers. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), corneal curvature (K-steep, K-flat and K-mean), corneal diameter (WtW), and pupil diameter (PD) were measured with a LenStar LS 900® biometer at rest and during VM. The IOP was also measured at rest and during VM measurements were compared. RESULTS: The VM did not have any significant influence on AL, WtW, K-flat, and K-mean (p > 0.05), but it decreased K-steep significantly (p < 0.001). Moreover, CCT and ACD decreased significantly during VM (p < 0.001), but VM increased IOP, PD (p < 0.001), and LT significantly (p = 0.002). CONCLUSIONS: The VM might reversibly change in IOP and ocular biometry, so it should be considered during anterior segment examinations.
18
Giorgio Marchini, A. Pagliarusco, Andrea Toscano et al. · Ophthalmology · 1998 · 277 citations
Medicine, Ophthalmology, Surgery +8