2008 · 11 citations · 8 references
EngineeringAerospace EngineeringAerodynamicsExperimental PerformancePerformance MeasurementPressure SystemsRotor DynamicsRotordynamicsStall DynamicsTransient Flow AnalysisCompressor AerodynamicsCompressor PerformanceCompressor StallCompressor SystemsMass Flow MeasurementPressure TransducersStagnation PointsUnsteady Aerodynamics In Stall
The performance, efficiency, and stall inception of an axial compressor was investigated experimentally with small levels of rotor centerline offset. The measurements were acquired using a high-speed, single-stage compressor. The rotor was levitated magnetically during operation which allowed precise positioning of the rotor centerline within the circular casing. The offset magnitude used in this study was 0.23% of the rotor tip chord, equivalent to approximately 24% of the nominal gap value. The resulting asymmetry in the tip gap resulted in circumferential and radial variations in the measured stagnation pressure and stagnation temperature downstream of the stage. However, the spatially averaged performance of the compressor was not measurably different from that obtained with a concentric rotor. An array of unsteady (Kulite) pressure transducers was used to investigate the flow field during stall inception. These measurements were recorded during transient throttle movements which quickly decreased the mass flow in the compressor until the onset of rotating stall. A second set of measurements was acquired during quasi-transient throttling starting from a mass flow about 1% larger than the stalling mass flow. In both the symmetric and offset cases the flow breakdown was consistent with spike type inception. The measurements with offset indicated that the asymmetries in the local compressor flow field produced significant changes in the number of short-length scale rotating disturbances observed during throttling to stall. These disturbances appeared in the region of the annulus where the local flow coefficient was lowest and usually decayed upon rotating to the higher flow region. In this way, the addition of very small amounts of rotor offset tended to fix the disturbance generation location in the stationary reference frame. This was in contrast to the symmetric tip clearance case where the location of spike generation appeared stochastic.
8
Criteria for Spike Initiated Rotating Stall
Huu Duc Vo, C. S. Tan, E. M. Greitzer · Journal of Turbomachinery · 2008 · 496 citations