Dynamic load shedding for shipboard power systems using the non-intrusive load monitor

Arun Shrestha, Edward L. Foulks, Robert W. Cox

2009 · 20 citations · 8 references

Concepts

Abstract

This paper presents a dynamic load-shedding scheme that uses a network of non-intrusive load monitors (NILMs). These devices, which can monitor the status of multiple loads using only a single set of aggregate voltage and current transducers, can log important real-time information about individual loads. This information can be used as part of a dynamic load-shedding scheme. The proposed approach is tested using a simulation model constructed in the alternative transients program (ATP). Results demonstrate its effectiveness.

References

8