Diabetes Care · 2010 · 230 citations · 17 references
PharmacyEndocrinologyPharmacotherapyDiabetologyDrug DeliveryOral Drug DeliveryBlood Glucose MonitoringDiabetes ManagementDiabetes MellitusGlucagon TherapyGlycemic ControlHypoglycemia ManagementAdult Hypoglycemia TreatmentBlood Glucose CorrectionBlood Glucose RegulationClosed-loop Delivery SystemsClosed-loop Insulin DeliveryClosed-loop Insulin TherapyGlucagon TreatmentSubcutaneous Glucagon
OBJECTIVE: To minimize hypoglycemia in subjects with type 1 diabetes by automated glucagon delivery in a closed-loop insulin delivery system. RESEARCH DESIGN AND METHODS: Adult subjects with type 1 diabetes underwent one closed-loop study with insulin plus placebo and one study with insulin plus glucagon, given at times of impending hypoglycemia. Seven subjects received glucagon using high-gain parameters, and six subjects received glucagon in a more prolonged manner using low-gain parameters. Blood glucose levels were measured every 10 min and insulin and glucagon infusions were adjusted every 5 min. All subjects received a portion of their usual premeal insulin after meal announcement. RESULTS: Automated glucagon plus insulin delivery, compared with placebo plus insulin, significantly reduced time spent in the hypoglycemic range (15 +/- 6 vs. 40 +/- 10 min/day, P = 0.04). Compared with placebo, high-gain glucagon delivery reduced the frequency of hypoglycemic events (1.0 +/- 0.6 vs. 2.1 +/- 0.6 events/day, P = 0.01) and the need for carbohydrate treatment (1.4 +/- 0.8 vs. 4.0 +/- 1.4 treatments/day, P = 0.01). Glucagon given with low-gain parameters did not significantly reduce hypoglycemic event frequency (P = NS) but did reduce frequency of carbohydrate treatment (P = 0.05). CONCLUSIONS: During closed-loop treatment in subjects with type 1 diabetes, high-gain pulses of glucagon decreased the frequency of hypoglycemia. Larger and longer-term studies will be required to assess the effect of ongoing glucagon treatment on overall glycemic control.
17
HEPATOCELLULAR CARCINOMA AND HEPATITIS B VIRUS
R. Palmer Beasley, Chia‐Chin Lin, Lu‐Yu Hwang et al. · The Lancet · 1981 · 2.9K citations
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Garry M. Steil, Kerstin Rebrin, Christine Darwin et al. · Diabetes · 2006 · 467 citations · Full text
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Motoaki Shichiri, Yoshimitsu Yamasaki, Ryuzo Kawamori et al. · The Lancet · 1982 · 311 citations