Cadmium Selective PVC-Membranes Sensor Based on 1, 2-Bis (Quinoline-2-Carboxamido) -4-Chlorobenzene as a Neutral Carrier

Behzad Rezaei, Soraia Meghdadi, Saeid Bagherpour

IEEE Sensors Journal · 2008 · 12 citations · 54 references

Concepts

Abstract

The 1, 2-bis(quinoline-2-Carboxamido)-4-chlorobenzene (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> Clbqb) was used as an excellent ionophore in the construction of a cadmium(II)-selective PVC-based membrane sensor. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with a membrane composition of (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> Clbqb) (5%): PVC (31%): DBP (61%): NaTPB (3%). The sensor shows a Nernestian response for cadmium ions over a wide concentration range (1.0times10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sup> to 1.0 times 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> mol.L <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> ) with slope of 30.3 plusmn0.4 mV decade <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sup> . The limit of detection was 8.0 times10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-7</sup> mol.L <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> . It illustrates a relatively fast response time in the whole concentration range (< 10 s) and it can be used for at least 8 weeks without any divergence in potential. The electrode can be used in the pH range from 2.4 to 9.0. The selectivity coefficient of some alkali, alkaline earth, transition and heavy metal ions towards Cd <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> ion have been determined. The results show proposed Cd sensor is selective over a number of mono, bi- and trivalent cations such as Pb <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3+</sup> , Ni <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , K <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> , and Mg <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> . The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. It was successfully applied for the direct determination of Cd <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> in standard and real sample solutions.

References

54