BJOG An International Journal of Obstetrics & Gynaecology · 1998 · 14 citations · 17 references
MedicineObstetricsPhysiologyMaternal-fetal MedicineObstetric UltrasoundPrenatal DiagnosisFetal AssessmentFetal BiometryFetal EchocardiographyFetal MonitoringGestational Age AssessmentMaternal-fetal PhysiologyBiometric Reference ValuesEvaluationFetal Heart Rate VariabilityFetal Heart Rate Variability AnalysisFetal Pulse OximetryGestational Age MeasurementOxygenationPostdate Pregnancy Management
Computerised fetal heart rate records were obtained between 1987 and 1993 using the Sonicaid System 8000 for a cross-sectional study of postdates fetal heart rate variation; 567 singleton pregnancies at 41 and 43 weeks provided 1502 records. In all cases gestational age had been verified by ultrasound examination in early pregnancy. The mean minute range of the long term pulse interval variation, which is known to be correlated with fetal oxygenation was found to decrease progressively from an average value of 48.5 ms at 41 weeks to 46.4 ms and 42.4 ms at 42 and 43 or more weeks, respectively. When conservative management of postdate pregnancies is chosen, accurate measurements are needed to follow the evolution of fetal condition. Reference values for calculated pulse interval variation at later gestational ages are now provided.
17
Short-term variation In abnormal antenatal fetal heart rate records
Philip Street, G. S. Dawes, M. Moulden et al. · American Journal of Obstetrics and Gynecology · 1991 · 183 citations
Medicine, Obstetrics, Physiology +12
James Walker · BJOG An International Journal of Obstetrics & Gynaecology · 1954 · 176 citations