European Heart Journal · 2010 · 248 citations · 15 references
MedicineSurgeryCardiothoracic SurgeryInterventional CardiologyCardiac Valve SurgeryMitral RegurgitationMitral Valve DiseaseMitral Valve InterventionTranscatheter Mitral Valve RepairTranscatheter Valve TherapyEdge-to-edge Valve RepairMitraclip TherapyMitral Valve Repair DevicesPercutaneous Mitral Valve RepairReal-world ApplicationResidual Mitral RegurgitationTranscatheter Edge-to-edge Repair
AIMS: This study sought to evaluate the feasibility and early outcomes of a percutaneous edge-to-edge repair approach for mitral valve regurgitation with the MitraClip system (Evalve, Inc., Menlo Park, CA, USA). METHODS AND RESULTS PATIENTS: were selected for the procedure based on the consensus of a multidisciplinary team. The primary efficacy endpoint was acute device success defined as clip placement with reduction of mitral regurgitation to < or =2+. The primary acute safety endpoint was 30-day freedom from major adverse events, defined as the composite of death, myocardial infarction, non-elective cardiac surgery for adverse events, renal failure, transfusion of >2 units of blood, ventilation for >48 h, deep wound infection, septicaemia, and new onset of atrial fibrillation. Thirty-one patients (median age 71, male 81%) were treated between August 2008 and July 2009. Eighteen patients (58%) presented with functional disease and 13 patients (42%) presented with organic degenerative disease. A clip was successfully implanted in 19 patients (61%) and two clips in 12 patients (39%). The median device implantation time was 80 min. At 30 days, there was an intra-procedural cardiac tamponade and a non-cardiac death, resulting in a primary safety endpoint of 93.6% [95% confidence interval (CI) 77.2-98.9]. Acute device success was observed in 96.8% of patients (95% CI 81.5-99.8). Compared with baseline, left ventricular diameters, diastolic left ventricular volume, diastolic annular septal-lateral dimension, and mitral valve area significantly diminished at 30 days. CONCLUSION: Our initial results with the MitraClip device in a very small number of patients indicate that percutaneous edge-to-edge mitral valve repair is feasible and may be accomplished with favourable short-term safety and efficacy results.
15
William A. Zoghbi, Maurice Enriquez‐Sarano, Elyse Foster et al. · Journal of the American Society of Echocardiography · 2003 · 4.1K citations · Full text
Medicine, Cardiology, Surgery +14
Alec Vahanian, Helmut Baumgartner, Jeroen J. Bax et al. · European Heart Journal · 2006 · 3.6K citations · Full text
Percutaneous Mitral Repair With the MitraClip System
Ted Feldman, Saibal Kar, Michael Rinaldi et al. · Journal of the American College of Cardiology · 2009 · 927 citations