IEEE Transactions on Energy Conversion · 1992 · 12 citations · 8 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesInduction MachinesTransient AnalysisDrive TransientsElectromechanical TransientsInduction Motor DrivesInverter ModelingStarting Transient AnalysisTransient Operating Behavior
The authors examine the starting transients of slip-energy recovery induction motor (IM) drives when started directly with the rotor rectifier. The starting transients of slip energy recovery IM drives comprising three stages are presented: starting from zero speed with a starting resistor connected to the output of the rectifier; the transmission period in which the inverter is connected through a DC link; and the final period when the starting resistor is disconnected from the rectifier output. A hybrid model is used which retains the actual rotor phase variables but transforms those of the stator only, to examine the starting transients of a slip energy recovery drive system.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
8