BULK SPECIFIC GRAVITY ROUND-ROBIN USING THE CORELOK VACUUM SEALING DEVICE

B D Prowell, L A Cooley, Mohd Rosli Hainin, M S Buchanan, J.F. Harrington

2002 · 35 citations · 5 references

Concepts

Abstract

This project conducted an evaluation of the Corelok device for the determination of the bulk specific gravity of compacted hot mix asphalt samples. The project consisted of the bulk specific gravity determination for compacted HMA mixes using the Corelok vacuum-sealing device and the SSD method (AASHTO T166). All samples were prepared by the National Center for Asphalt Technology (NCAT) and were provided to each participating laboratory for testing. Participating laboratories conducted the bulk specific gravity testing using both the Corelok device and SSD method. Test results were returned to NCAT for statistical analysis and determination of repeatability and reproducibility parameters for both methods. A total of 21 laboratories participated in this study. 18 of which returned test results. Each laboratory was provided a Corelok vacuum sealing device through the pooled-fund effort.

References

5