2002 · 11 citations · 7 references
MedicineAnatomyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyChest RadiologyImage CompressionImage QualityImage Quality AssessmentMagnetic Resonance ImagingMedical ImagingChest Magnetic Resonance ImagingCompression Performance EvaluationMagnetic ResonanceMeasurement AccuracyMedical Image CompressionMedical Image Quality AssessmentVector QuantizationWilcoxon Signed-rank Test
We investigated the effects of lossy image compression on measurement accuracy in magnetic resonance images. Thirty chest scans were compressed to five different levels using predictive pruned tree-structured vector quantization (predictive PTSVQ). Three radiologists measured the diameters of the four principal blood vessels on each image. Errors were analyzed relative to both an independent standard and personal performance on uncompressed images. Data were compared with both t and Wilcoxon tests. We conclude that for the purpose of measuring blood vessels in the chest, there is no significant difference in measurement accuracy when images are compressed up to 16:1 with predictive PTSVQ.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
7
Approximation Theory and Methods.
Lars B. Wahlbin, M. J. D. Powell · Mathematics of Computation · 1982 · 825 citations
Computed Body Tomography with MRI Correlation.
Annals of Internal Medicine · 1991 · 350 citations · Full text
Computed Body Tomography With MRI Correlation
Annals of Internal Medicine · 1989 · 287 citations · Full text
Data compression: effect on diagnostic accuracy in digital chest radiography.
Heber MacMahon, Kazuteru Doi, Shigeru Sanada et al. · Radiology · 1991 · 127 citations