Archives of Neurology · 1992 · 532 citations · 6 references
Health ProfessionsSpeech-language PathologyDysphagiaPhysical ExaminationSwallowing RehabilitationClinical Swallowing EvaluationDysphagia AssessmentDysphagia In StrokeOropharyngeal DysphagiaSwallowing AssessmentSwallowing DisordersBarium Swallow EvaluationClinical Swallow EvaluationClinical Swallowing ScreeningDiagnostic Swallowing EvaluationPost-stroke Dysphagia AssessmentSwallowing Assessment After StrokeSwallowing Evaluation In StrokeWater Swallow Test
A 3-oz water swallow test identified 80% (16/20) of patients aspirating during a subsequent videofluoroscopic modified barium swallow examination (sensitivity, 76%; specificity, 59%). It also identified patients with more severe dysphagia aspirating larger amounts (sensitivity, 94%; specificity, 26%) or thicker consistencies (sensitivity, 94%; specificity, 30%) of test material. The 3-oz water swallow test is a sensitive screening tool for identifying patients at risk for clinically significant aspiration who need referral for more definitive modified barium swallow evaluation.
6
Catherine M. Gordon, R L Hewer, Derick T Wade · BMJ · 1987 · 649 citations · Full text
Silent aspiration following stroke
Jennifer Horner, E. Wayne Massey · Neurology · 1988 · 442 citations
Health Professions, Neurology, Speech-language Pathology +14
Jack Homer, E W Massey, John E. Riski et al. · Neurology · 1988 · 356 citations