BMC Ophthalmology · 2004 · 64 citations · 40 references
MedicineOphthalmologyVision ScienceBiomedical OpticsClinical Vision ScienceVisual OpticsOcular BiometryOptical AberrationsMeasurementOcular Wavefront AberrationsOphthalmic Aberration MeasurementPupil DiameterShack-hartmann Wavefront SensingShack-hartmann Wavefront SensorsWavefront SensingZernike Polynomials
BACKGROUND: Recently, instruments for the measurement of wavefront aberration in the living human eye have been widely available for clinical applications. Despite the extensive background experience on wavefront sensing for research purposes, the information derived from such instrumentation in a clinical setting should not be considered a priori precise. We report on the variability of such an instrument at two different pupil sizes. METHODS: A clinical aberrometer (COAS Wavefront Scienses, Ltd) based on the Shack-Hartmann principle was employed in this study. Fifty consecutive measurements were performed on each right eye of four subjects. We compared the variance of individual Zernike expansion coefficients as determined by the aberrometer with the variance of coefficients calculated using a mathematical method for scaling the expansion coefficients to reconstruct wavefront aberration for a reduced-size pupil. RESULTS: Wavefront aberration exhibits a marked variance of the order of 0.45 microns near the edge of the pupil whereas the central part appears to be measured more consistently. Dispersion of Zernike expansion coefficients was lower when calculated by the scaling method for a pupil diameter of 3 mm as compared to the one introduced when only the central 3 mm of the Shack - Hartmann image was evaluated. Signal-to-noise ratio was lower for higher order aberrations than for low order coefficients corresponding to the sphero-cylindrical error. For each subject a number of Zernike expansion coefficients was below noise level and should not be considered trustworthy. CONCLUSION: Wavefront aberration data used in clinical care should not be extracted from a single measurement, which represents only a static snapshot of a dynamically changing aberration pattern. This observation must be taken into account in order to prevent ambiguous conclusions in clinical practice and especially in refractive surgery.
40
Dynamics of the eye’s wave aberration
Heidi Hofer, Pablo Artal, Ben Singer et al. · Journal of the Optical Society of America A · 2001 · 358 citations
Medicine, Ophthalmology, Physics +15
Infrared imaging of sub-retinal structures in the human ocular fundus
Ann E. Elsner, Stephen A. Burns, John J. Weiter et al. · Vision Research · 1996 · 310 citations
The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans
Larry N. Thibos, Ming Ye, Xiaoxiao Zhang et al. · Applied Optics · 1992 · 309 citations