Journal of Applied Physiology · 2015 · 59 citations · 22 references
EducationHealth InformaticsHealth-related FitnessMovement AnalysisPhysical ActivityMovement Pattern AnalysisPhysical Activity AssessmentSedentary BehaviorLaboratory Data AcquisitionObjective Physical Activity AssessmentPhysical Activity MonitoringPhysical Activity Pattern AnalysisSedentary Behavior AssessmentSedentary Behavior MeasurementSedentary Behavior PatternsSedentary Behaviour
"Objective" methods to monitor physical activity and sedentary patterns in free-living conditions are necessary to further our understanding of their impacts on health. In recent years, many software solutions capable of automatically identifying activity types from portable accelerometry data have been developed, with promising results in controlled conditions, but virtually no reports on field tests. An automatic classification algorithm initially developed using laboratory-acquired data (59 subjects engaging in a set of 24 standardized activities) to discriminate between 8 activity classes (lying, slouching, sitting, standing, walking, running, and cycling) was applied to data collected in the field. Twenty volunteers equipped with a hip-worn triaxial accelerometer performed at their own pace an activity set that included, among others, activities such as walking the streets, running, cycling, and taking the bus. Performances of the laboratory-calibrated classification algorithm were compared with those of an alternative version of the same model including field-collected data in the learning set. Despite good results in laboratory conditions, the performances of the laboratory-calibrated algorithm (assessed by confusion matrices) decreased for several activities when applied to free-living data. Recalibrating the algorithm with data closer to real-life conditions and from an independent group of subjects proved useful, especially for the detection of sedentary behaviors while in transports, thereby improving the detection of overall sitting (sensitivity: laboratory model = 24.9%; recalibrated model = 95.7%). Automatic identification methods should be developed using data acquired in free-living conditions rather than data from standardized laboratory activity sets only, and their limits carefully tested before they are used in field studies.
22
Breaking Up Prolonged Sitting Reduces Postprandial Glucose and Insulin Responses
David W. Dunstan, Bronwyn A. Kingwell, Robyn N. Larsen et al. · Diabetes Care · 2012 · 1.2K citations · Full text
Medicine, Endocrinology, Nutrition +14
Stephen Preece, John Y. Goulermas, Laurence Kenney et al. · IEEE Transactions on Biomedical Engineering · 2008 · 544 citations · Full text