International Journal of Energy Research · 2006 · 114 citations · 4 references
ArchitectureArchitectural EngineeringBuilding ScienceBuilding Performance SimulationEnergy EconomicsEnergy ManagementBuilding Energy ModelingBuilding Energy PerformanceBuilding Energy SystemsBuilding Performance AssessmentEnergy MeteringEnergy UseEnergy BenchmarkingEnergy Consumption AnalysisEnergy Performance EvaluationEnergy Use IntensityMulti-linear RegressionNeural Network ModelingPhysical PropertiesPrediction Model Development
This study develops an energy benchmarking model using the U.S. Commercial Buildings Energy Consumption Survey database. The model employs an artificial neural network trained on office building data from CBECS, using physical, occupancy, and climate variables to predict weighted energy use intensity (EUI) per square meter. The ANN model achieved correlation coefficients between 0.45 and 0.73 and mean squared errors from 9.60 to 15.25, outperforming multivariate regression models (MSE 10.24–40.43) and showing higher accuracy when data were grouped by climate zone.
This study focuses on development of an energy benchmarking model utilizing U.S. Commercial Buildings Energy Consumption Survey (CBECS) Database. An artificial neural networks (ANN) method based approach was used in the study. Office type buildings in the CBECS database were used in the benchmarking model development and weighted energy use intensity (EUI) was selected as the benchmarking index. The benchmarking model included input variables describing building's physical properties, occupancy and climate. Yearly electricity consumption per square meter, or EUI, was estimated by the ANN model. The correlation coefficient for each census division benchmarking model varied between 0.45 and 0.73, and mean squared error (MSE) varied between 9.60 and 15.25. It was observed that when the data set for a census division was grouped by different climate zones, ANN benchmarking model provided more accurate predictions. It was also observed that ANN model provides more accurate estimations when compared with predictions obtained with multi-linear regression models. For comparison, the MSE values varied between 10.24 and 40.43. Overall, the ANN model proved itself a better prediction model for energy benchmarking. Copyright © 2006 John Wiley & Sons, Ltd.
4