MedicineNeurologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingNeuroimaging PhysicsCerebral MicrobleedsField Strength DependenceGradient Echo SequencesMagnetic Field StrengthMagnetic Resonance Imaging Lesion DetectionMicrobleed ImagingMicrohemorrhage DetectionSusceptibility-weighted Imaging
BACKGROUND AND PURPOSE: The emergence of cerebral microbleeds (CMB) as common MR imaging findings raises the question of how MR imaging parameters influence CMB detection. To evaluate the effects of modified gradient recalled-echo (GRE) MR imaging methods, we performed an analysis of sequence, section thickness, and field strength on CMB imaging properties and detection in subjects with cerebral amyloid angiopathy (CAA), a condition associated with microhemorrhage. MATERIALS AND METHODS: Multiple MR images were obtained from subjects with probable CAA, with varying sequences (GRE versus susceptibility-weighted imaging [SWI]), section thicknesses (1.2-1.5 versus 5 mm), and magnetic field strengths (1.5T versus 3T). Individual CMB were manually identified and analyzed for contrast index (lesion intensity normalized to normal-appearing white matter signal intensity) and diameter. CMB counts were compared between 1.5T thick-section GRE and thin-section SWI for 3 subjects who underwent both protocols in the same scanning session. RESULTS: With other parameters constant, use of SWI, thinner sections, and a higher field strength yielded medium-to-large gains in CMB contrast index (CI; Cohen d 0.71-1.87). SWI was also associated with small increases in CMB diameter (Cohen d <0.3). Conventional thick-section GRE identified only 33% of CMB (103 of 310) seen on thin-section SWI. Lesions prospectively identified on GRE had significantly greater CI and diameter measured on the GRE image than those not prospectively identified. CONCLUSIONS: The examined alternatives to conventional GRE MR imaging yield substantially improved CMB contrast and sensitivity for detection. Future studies based on these techniques will most likely yield even higher prevalence estimates for CMB.
32
Susceptibility weighted imaging (SWI)
E. Mark Haacke, Yingbiao Xu, Yu‐Chung N. Cheng et al. · Magnetic Resonance in Medicine · 2004 · 1.6K citations
Clinical diagnosis of cerebral amyloid angiopathy: Validation of the Boston Criteria
Katherine Knudsen, Jonathan Rosand, Diane Karluk et al. · Neurology · 2001 · 1K citations
Franz Fazekas, R. Kleinert, Gudrun Roob et al. · PubMed · 1999 · 934 citations · Full text