Coronary Vein Angioplasty with Noncompliant Balloon for Resistant Coronary Vein Stenosis During Left Ventricular Lead Implantation

KETUL CHAUHAN, Dany Sayad, Richard E. Bowerman, S. Serge Barold

Pacing and Clinical Electrophysiology · 2008 · 10 citations · 6 references

DOIFull text

Open access

Concepts

Abstract

This report describes a patient who underwent cardiac resynchronization therapy (CRT) in the setting of a severe stenosis in the lateral coronary vein that prevented passage of a left ventricular lead. The stenosis was unresponsive to standard compliant balloon dilatation but was successfully treated with a noncompliant balloon. Venoplasty with noncompliant balloon should be considered for resistant coronary vein stenosis encountered during CRT device implantation.

References