Health ProfessionsInfectious DiseasesRespiratory TherapyPulmonologyVentilationVentilator ManagementAcute Respiratory Distress SyndromeAcute Respiratory Distress Syndrome VentilationLung-protective VentilationMechanical VentilationVentilation Performance EvaluationVentilation RequirementsHumidificationHumidification TherapyIntensive Care UseMechanical Ventilation ManagementRespiratory Circuit HumidifiersVentilator-associated PneumoniaVentilator-associated Pneumonia CoverageVentilator-associated Pneumonia Risk
OBJECTIVE: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). DESIGN: A prospective, randomized trial. SETTING: A metropolitan teaching hospital's general intensive care unit. PATIENTS: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. INTERVENTIONS: Patients were randomized to humidification with use of an HME (n=190), SHW (n=94), or DHW (n=97). MEASUREMENTS AND MAIN RESULTS: Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p=0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p=.03) and ventilation days (AOR, 1.05; 95% CI, 1.0-1.2; p=.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% CI, 0.4-0.2; p=.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p=.2), as were suction frequency, secretion thickness, and blood on suctioning (p=.32, p=.06, and p=.34, respectively). The HME use per patient per day was 1.13. CONCLUSIONS: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
38
Manual of Clinical Microbiology.
Annals of Internal Medicine · 1980 · 14.5K citations
William A. Knaus, Elizabeth A. Draper, Douglas P. Wagner et al. · Critical Care Medicine · 1985 · 13.7K citations
Medicine, Internal Medicine, Clinical Classification Systems +16
Standards for the Diagnosis and Care of Patients with Chronic Obstructive Pulmonary Disease
Bartolomé R. Celli, Gordon L. Snider, John E. Heffner et al. · 1995 · 3.5K citations
Medicine, Surgery, Exercise Testing +16
Power and sample size calculations
William D. Dupont, W. Dale Plummer · Controlled Clinical Trials · 1990 · 2.1K citations