IEEE Transactions on Biomedical Engineering · 1978 · 17 citations · 5 references
EngineeringNeuroscienceElectrophysiologyNeural EngineeringTime Series AnalysisDigital Signal ProcessingNeural Data AnalysisNeural Recording TechnologiesNeural Signal AcquisitionNeural Signal ProcessingSignal ProcessingAliasingAliasing ErrorCutoff FrequencyNeural RecordingNeural SamplingNeural Spike Train AnalysisNyquist FrequencySpike Trains
The French-Holden algorithm (1), (2), (3) provides a sampled data time series representation of a neuronal spike train in order to facilitate subsequent analyses by conventional signal processing techniques. Two characteristics of this filtering algorithm make the choice of data record length particularly important: (a) an ideal, sharp cutoff filter is used on the spike train, and (b) the Nyquist sampling frequency is chosen exactly equal to the filter cutoff frequency. In this note, sources of distortion and aliasing errors due to finite data records are discussed and guidelines for the selection of minimum record length are given.
5
Alias-free sampling of neuronal spike trains
Andrew S. French, Arun V. Holden · Kybernetik · 1971 · 178 citations