Circulation Arrhythmia and Electrophysiology · 2008 · 264 citations · 31 references
MedicineCardiologyCardiothoracic SurgeryClinical CardiologyInterventional CardiologyCardiac ArrhythmiasCardiac Risk AssessmentCongenital Heart DiseaseCongenital Heart SurgeryImplantable Cardioverter-defibrillator CareSudden Cardiac Death PreventionCongenital Heart Defects EpidemiologyCongenital Heart Disease - Associated ArrhythmiasImplantable Cardioverter DefibrillatorsLife-threatening ArrhythmiasSudden Cardiac Death Risk AssessmentSudden Death PreventionSudden Death Risk Assessment
BACKGROUND: Transposition of the great arteries with intra-atrial baffle repair is among the congenital heart defects at highest risk of sudden death. Little is known about mechanisms of sudden death and the role of implantable cardioverter defibrillators. METHODS AND RESULTS: We conducted a multicenter cohort study in patients with transposition of the great arteries to determine actuarial rates of implantable cardioverter defibrillator shocks, identify risk factors, assess underlying arrhythmias, and characterize complications. Overall, 37 patients (age, 28.0+/-7.6 years; 89.2% male) were enrolled from 7 sites. Implantable cardioverter defibrillators were implanted for primary prevention in 23 (62.1%) patients and secondary prevention in 14 patients (37.8%). Annual rates of appropriate shocks were 0.5% and 6.0% in primary and secondary prevention, respectively (P=0.0366). Independent predictors were a secondary prevention indication (hazard ratio, 18.0; P=0.0341) and lack of beta-blockers (hazard ratio, 16.7; P=0.0301). In patients with appropriate shocks, intracardiac electrograms documented supraventricular tachycardia preceding or coexisting with ventricular tachycardia in 50%. No patient with inducible ventricular tachycardia received an appropriate shock in comparison with 37.5% of noninducible patients (P=0.0429). Inappropriate shocks occurred in 6.6% per year, more so in patients of lesser weight (hazard ratio, 0.91 per kg; P=0.0168). Additionally, 14 patients (37.8%) experienced complications: 5 (13.5%) acute, 1 (2.7%) late generator related, and 12 (32.4%) late lead related. CONCLUSIONS: In patients with transposition of the great arteries, high rates of appropriate shocks are noted in secondary but not primary prevention. Supraventricular arrhythmias may be implicated in the etiology of ventricular tachyarrhythmias; beta-blockers seem protective, and inducible ventricular tachycardia does not seem to predict future events. Inappropriate shocks and late lead-related complications are common.
31
SUCCESSFUL TWO-STAGE CORRECTION OF TRANSPOSITION OF THE GREAT VESSELS.
W.T. Mustard · PubMed · 1964 · 684 citations
Surgical Correction of Transposition of the Great Vessels
Elmore M. Aronstam, Thomas H. Hewlett, James A. Orbison et al. · Annals of Surgery · 1963 · 593 citations · Full text
Implantable Cardioverter-Defibrillators in Tetralogy of Fallot
Paul Khairy, Louise Harris, Michael J. Landzberg et al. · Circulation · 2008 · 552 citations