American Journal of Roentgenology · 2012 · 175 citations · 18 references
MedicineRadiologyInterventional RadiologyRadiation ProtectionRadiation SafetyEquivalent DoseOccupational MedicineOccupational Radiation ProtectionOccupational Radiation SafetyPersonnel DosimetryRadiation Dose MeasurementOccupational Dose EstimationOccupational Dose MonitoringOccupational Radiation MonitoringOccupational Radiation Risk AssessmentProcedure-related Radiation SafetyRadiation Dose AssessmentRadiation Dose MonitoringRadiologic Imaging
Interventional radiology involves long fluoroscopic procedures, making radiation protection for staff a critical concern. The study aims to clarify the annual occupational radiation dose levels for interventional radiology staff, particularly nurses, and to recommend using two monitoring badges for accurate dose assessment. The authors recorded annual occupational doses for 18 physicians, seven nurses, and eight technologists using two monitoring badges worn over and under lead aprons, yielding mean effective doses of 3.00, 1.34,.
Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses.We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons.The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method.The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.
18
Eye Lens Exposure to Radiation in Interventional Suites: Caution Is Warranted
E. Vañó, Luciano González, J. Fernández et al. · Radiology · 2008 · 255 citations
Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
Koichi Chida, Tadayuki Ohno, Shuhei Kakizaki et al. · American Journal of Roentgenology · 2010 · 137 citations
Medicine, Pediatrics, Radiology +17