MedicineNeurosurgeryRadiation OncologyCentral Nervous System Radiation OncologyRadiation ProtectionTreatment PlanningBrain TumorsRadiation TherapyRadiation Treatment PlanningStereotactic RadiosurgeryStereotactic RadiotherapyCavernous Sinus TumorsFlattening Filter-free BeamsStereotactic Radiosurgery DosimetryTreatment Efficiency AssessmentTreatment Plan EvaluationTreatment Plan OptimizationVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
BACKGROUND: To evaluate the role of RapidArc (RA) for stereotactic radiosurgery (SRS) of benign brain lesions in comparison to GammaKnife (GK) based technique. METHODS: Twelve patients with vestibular schwannoma (VS, n = 6) or cavernous sinus meningioma (CSM, n = 6) were planned for both SRS using volumetric modulated arc therapy (VMAT) by RA. 104 MV flattening filter free photon beams with a maximum dose rate of 2400 MU/min were selected. Data were compared against plans optimised for GK. A single dose of 12.5 Gy was prescribed. The primary objective was to assess treatment plan quality. Secondary aim was to appraise treatment efficiency. RESULTS: For VS, comparing best GK vs. RA plans, homogeneity was 51.7 ± 3.5 vs. 6.4 ± 1.5%; Paddick conformity Index (PCI) resulted 0.81 ± 0.03 vs. 0.84 ± 0.04. Gradient index (PGI) was 2.7 ± 0.2 vs. 3.8 ± 0.6. Mean target dose was 17.1 ± 0.9 vs. 12.9 ± 0.1 Gy. For the brain stem, D(1cm3) was 5.1 ± 2.0 Gy vs 4.8 ± 1.6 Gy. For the ipsilateral cochlea, D(0.1cm3) was 1.7 ± 1.0 Gy vs. 1.8 ± 0.5 Gy. For CSM, homogeneity was 52.3 ± 2.4 vs. 12.4 ± 0.6; PCI: 0.86 ± 0.05 vs. 0.88 ± 0.05; PGI: 2.6 ± 0.1 vs. 3.8 ± 0.5; D(1cm3) to brain stem was 5.4 ± 2.8 Gy vs. 5.2 ± 2.8 Gy; D(0.1cm3) to ipsi-lateral optic nerve was 4.2 ± 2.1 vs. 2.1 ± 1.5 Gy; D(0.1cm3) to optic chiasm was 5.9 ± 3.1 vs. 4.5 ± 2.1 Gy. Treatment time was 53.7 ± 5.8 (64.9 ± 24.3) minutes for GK and 4.8 ± 1.3 (5.0 ± 0.7) minutes for RA for schwannomas (meningiomas). CONCLUSIONS: SRS with RA and FFF beams revealed to be adequate and comparable to GK in terms of target coverage, homogeneity, organs at risk sparing with some gain in terms of treatment efficiency.
23
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
The Cyberknife: A Frameless Robotic System for Radiosurgery
John R. Adler, Steven D. Chang, Martin J. Murphy et al. · Stereotactic and Functional Neurosurgery · 1998 · 664 citations
Medicine, Neurosurgery, Surgery +15
L. G. Leksell · Journal of Neurology Neurosurgery & Psychiatry · 1983 · 523 citations · Full text