European Heart Journal - Cardiovascular Imaging · 2014 · 47 citations · 24 references
MedicineCardiologyRadiologyBiomedical ImagingCardiothoracic RadiologyClinical CardiologyCardiac AssessmentCardiac ImagingCardiovascular ImagingCoronary Artery DiseaseMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingBlood FlowCoronary Flow Reserve AssessmentFramingham Risk ScoreMyocardial Flow ReserveMyocardial Perfusion ReserveRest Myocardial Perfusion ImagingResting Myocardial PerfusionStress Myocardial Blood Flow Quantification
AIMS: The aim of the study was to measure rest and stress myocardial blood flow (MBF) values prospectively in a low-risk population with 128-slice dual-source computed tomography (CT) and to compare MBF/coronary flow reserve (CFR) values to that of a second population with a documented coronary artery disease (CAD). METHODS AND RESULTS: This study evaluates resting and hyperaemic MBF in 35 low-risk individuals identified by the modified Framingham Risk score and a calcium score of <100. The patients were scanned using 80 kV and quantitative blood flow values were generated using complete time-attenuation curves. Global resting and hyperaemic MBF was 74.08 ± 16.30 and 135.24 ± 28.89 mL/100 g/min, respectively, with CFR of 1.86 ± 0.38. Resting MBF was 76.98 ± 25.68, 66.98 ± 19.66, 81.34 ± 21.40, and 63.35 ± 16.35 mL/100 g/min in anterior, septal, lateral, and inferior walls, respectively, and corresponding hyperaemic MBF was 133.25 ± 29.80, 123.47 ± 31.03, 148.60 ± 32.69, and 124.21 ± 31.54 mL/100 g/min, respectively. In the population with CAD, global resting and hyperaemic MBF were 82.29 ± 16.87 and 81.98 ± 18.54 mL/100 g/min and 107.95 ± 25.25 and 106.93 ± 32.91 mL/100 g/min in the group with ischaemia only and infarction only, respectively, with corresponding CFR of 1.33 ± 0.27 and 1.33 ± 0.46, respectively (statistically different from the low-risk population). Radiation dose for CT myocardial perfusion imaging (CTMPI) was 6.72 ± 2.71 and 6.19 ± 2.19 mSv for stress and rest scans, respectively. This was 30% lower than a radiation dose in the scanning historical cohort at 100 kV. There was no significant difference in the signal-to-noise ratio and contrast-to-noise ratio between low-risk cohort and historical cohort scanned at 80 and 100 kV, respectively. CONCLUSIONS: Baseline, hyperaemic MBF and CFR values in a low-risk cohort can be evaluated with dynamic myocardial perfusion imaging using 80 kV.
24
Philip Greenland, Robert O. Bonow, Bruce H. Brundage et al. · Journal of the American College of Cardiology · 2007 · 961 citations
Philip Greenland, Robert O. Bonow, Bruce H. Brundage et al. · Circulation · 2007 · 934 citations
Carlos Eduardo Rochitte, Richard T. George, Marcus Y. Chen et al. · European Heart Journal · 2013 · 436 citations · Full text
Medicine, Cardiology, Radiology +17