ACS Sustainable Chemistry & Engineering · 2013 · 17 citations · 11 references
EngineeringChemical EngineeringChemistryCombustionFire ManagementFire Protection EngineeringFire SafetyFire TestingIgnitionBindersCandidate ReplacementElectrostatic DischargeElectrostatic Discharge TestingReplacementSensitivitySmoke Composition
We report herein the development of an environmentally benign yellow smoke formulation aimed to replace the environmentally hazardous mixture currently specified for the U.S. Army’s M194 yellow smoke hand-held signal. Static ignition test measurements have identified a replacement candidate that generates a robust fountain of yellow smoke, burning for 15 s from a consolidated cardboard tube configuration. This new formulation meets the burn time parameters outlined in the military requirement and is composed entirely of dry, powdered, solid ingredients without the need for solvent-based binders. In addition, this formulation was found to have relatively low sensitivity to impact, friction, and electrostatic discharge.
11