Electricity storage for intermittent renewable sources

Jason Rugolo, Michael J. Aziz

Energy & Environmental Science · 2012 · 240 citations · 6 references

DOIFull text

Open access

Concepts

TL;DR

With sufficient electricity storage capacity, any power production profile can be mapped onto any desired supply profile. The authors present a framework to compute the time‑varying storage power needed for any production and supply profile, targeting a specified system efficiency while accounting for storage loss characteristics. They apply the framework to electrochemical storage of intermittent renewable power, using a linear response approximation that reduces the entire efficiency behavior to a single scalar figure of merit—the discharge power capacity, and evaluate it across three grid supply scenarios (constant, grid‑minus‑baseload, square wave) and two production scenarios (wind, 32.5 % capacity factor, and solar PV, 14 % capacity factor). The analysis shows that for each of the six production‑supply combinations, storage energy and discharge power capacity requirements vary with system efficiency, that efficiency gains diminish as discharge power capacity increases, and that solid‑electrode batteries possess an energy‑to‑power ratio two orders of magnitude too low for intermittent renewable storage.

Abstract

With sufficient electricity storage capacity, any power production profile may be mapped onto any desired supply profile. We present a framework to determine the required storage power as a function of time for any power production profile, supply profile, and targeted system efficiency, given the loss characteristics of the storage system. We apply the framework to the electrochemical storage of intermittent renewable power, employing a simplifying linear response approximation that permits the entire efficiency behavior of the system to be described by a single scalar figure of merit—the discharge power capacity. We consider three exemplary grid supply scenarios: constant, grid-minus-baseload, and square wave; and two different production scenarios: wind with a capacity factor 32.5%, and solar photovoltaic (PV) with a capacity factor of 14%. For each of these six combinations of scenarios, the storage energy and discharge power capacity requirements are found for a range of system efficiencies. Significantly diminishing efficiency returns are found on increasing the discharge power capacity. Solid-electrode batteries are shown to have two orders of magnitude too little energy to power ratio to be well suited to the storage of intermittent renewable power.

References

6