IEEE Transactions on Applied Superconductivity · 2005 · 39 citations · 8 references
Natural SciencesElectrical EngineeringPhysicsCondensed Matter PhysicsElectromagneticsPower ElectronicsElectrical InstallationHigh-temperature MaterialsInsulation MaterialsSuperconducting MaterialsThree-phase CircuitsAc LossesCable System DesignCable SystemsHigh-temperature SuperconductorsPower Cable DesignSuperconducting Cable DesignSuperconducting PropertiesSuperconducting Tapes
The Ultera/ORNL team have built and tested 3-m and 5-m triaxial cables rated at 3 and 1.3 kA-rms, respectively. The three concentric superconducting phases are made of BSCCO-2223 HTS tapes, separated by layers of cold-dielectric tapes. A copper braid is added as the grounding shield on the outside of the three active phases. Tests of these cables were performed at temperatures ranging from 70 to 84 K. AC loss data reconfirmed the previous result on a 1.5-m prototype cable that the total 3-phase ac loss is about the sum of the calculated ac losses of the three concentric phases. These and other test results of the 1.3 and 3 kA cables will be used to construct a second 5-m triaxial cable rated at 3 kA-rms, 15 kV. Preliminary test results supporting this new cable and the associated termination are summarized.
8
Fault current tests of a 5-m HTS cable
J.W. Lue, G. C. Barber, Jonathan Demko et al. · IEEE Transactions on Applied Superconductivity · 2001 · 27 citations · Full text