Journal of Cardiovascular Pharmacology and Therapeutics · 1999 · 12 citations · 28 references
MedicineCardiologyPhysiologyElectrophysiologyInterventional CardiologyPhysiological Systems ModelingAtrial ElectrophysiologyCardiac ArrhythmiasCardiac Conduction SystemCardiac PacingCardiac PhysiologyElectrocardiographyAtrial Arrhythmia MechanismsAtrial Conduction VelocityAtrial Electrical RemodelingAtrial Fibrillation PathophysiologyAtrial Refractory PeriodCardiac Activation MappingProgrammed Electrical StimulationRemodeling
BACKGROUND: The electrophysiologic mechanisms of the persistence of atrial fibrillation (AF) after its initiation are not well understood. Therefore, the electrophysiologic characteristics of the right atrium were evaluated in an acute, pacing-induced model of AF in the pig in order to identify parameters associated with persistence of AF. METHODS AND RESULTS: AF was induced by rapid atrial pacing in 30 anesthetized, open-chest, juvenile pigs. Sustained (S) AF was defined as that lasting >10 minutes, nonsustained (NS) AF <10 minutes but >30 seconds, and no (N) AF <30 seconds. Activation mapping and programmed stimulation (S1S1 = 200 ms) was performed at 56 electrodes on the right atrial free wall, to determine ERP (mean and minimum), dispersion of refractoriness (ERPdisp, ELEdisp), conduction velocity (CV), wavelength, AF cycle length (mean of 10 beats), and AF cycle length/time (electrical remodeling). SAF was induced in 10 pigs, NSAF in 9, and NAF in 11. AF cycle length was shorter in SAF and/vs NS vs NAF (P <.001). Mean ERP (107 +/- 9 and/vs 122 +/- 5 vs 142 +/- 9, p <.001) and wavelength (7 +/- 1 and/vs 9 +/- 1 vs 11 +/- 1, P <.001) were shorter in SAF and/vs NSAF vs NAF. Minimum ERP was shorter in SAF and NSAF vs NAF (P <.001). CV at cycle lengths of 200 and 150 msec was not different between groups. Dispersion of ERP was greater in SAF and/vs NSAF vs NAF (8 +/- 1 and/vs 11 +/- 1 vs 19 +/- 4, P <.001). CONCLUSIONS: Persistence of AF correlated with shorter ERP and wavelength, and greater dispersion of ERP and electrical remodeling. There was no correlation with CV.
28
Atrial Fibrillation Begets Atrial Fibrillation
M. C. E. F. Wijffels, C Kirchhof, Rick Dorland et al. · Circulation · 1995 · 3.5K citations
Epidemiologic Features of Chronic Atrial Fibrillation
William B. Kannel, Robert D. Abbott, Daniel D. Savage et al. · New England Journal of Medicine · 1982 · 2.3K citations
A computer model of atrial fibrillation
Gordon K. Moe, Werner C. Rheinboldt, J.A. Abildskov · American Heart Journal · 1964 · 1.3K citations
Medicine, Cardiology, Physiology +14
Maurits A. Allessie, F. I. M. Bonke, Francien J. G. Schopman · Circulation Research · 1977 · 1.1K citations
Medicine, Cardiology, Physiology +11
Carlos A. Morillo, George J. Klein, Douglas L. Jones et al. · Circulation · 1995 · 1K citations