Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · 2013 · 17 citations · 7 references
DentistryMaxillofacial RadiologyOral RadiologyDental RadiologyDiagnostic ImagingMaxillofacial ImagingComputed TomographyDental ImagingDental RadiographyDigital Dental ImagingIntraoral RadiographyThree-dimensional ReconstructionCone-beam Computed Tomography (Cbct)Detector Spatial ResolutionModulation Transfer FunctionModulation Transfer Function AnalysisSpatial Resolution AnalysisSpatial Resolution Measurement
ObjectiveThis study evaluates the spatial resolution of cone beam computed tomography for dental use (CBCT) via modulation transfer function (MTF) analyses.Study DesignTwo models of CBCT system, 3DX FPD8 and FineCube v.12, were used. MTF analysis was applied to each CBCT system using a thin tungsten wire technique.ResultsThe MTF curves in the radial direction on the XY-plane were concordant regardless of position, whereas the curves in the azimuthal direction tended to decrease as the distance from the rotation center increased. In the Z-axis direction, the MTF curve of the medial level of the field of view was superior to that of any other level.ConclusionThe spatial resolution of CBCT systems depends on the location within the field of view. Because the spatial resolution was the highest in the medial level and rotation center position, an object should be placed at this position during a CBCT examination. This study evaluates the spatial resolution of cone beam computed tomography for dental use (CBCT) via modulation transfer function (MTF) analyses. Two models of CBCT system, 3DX FPD8 and FineCube v.12, were used. MTF analysis was applied to each CBCT system using a thin tungsten wire technique. The MTF curves in the radial direction on the XY-plane were concordant regardless of position, whereas the curves in the azimuthal direction tended to decrease as the distance from the rotation center increased. In the Z-axis direction, the MTF curve of the medial level of the field of view was superior to that of any other level. The spatial resolution of CBCT systems depends on the location within the field of view. Because the spatial resolution was the highest in the medial level and rotation center position, an object should be placed at this position during a CBCT examination.
7
Evaluation of the spatial resolution characteristics of a cone‐beam breast CT scanner
Alexander L. C. Kwan, John M. Boone, Kai Yang et al. · Medical Physics · 2006 · 126 citations
Weeraya Tantanapornkul, Kiyoshi Okochi, Anonknart Bhakdinaronk et al. · Dentomaxillofacial Radiology · 2008 · 94 citations