Radiation Protection Dosimetry · 2009 · 12 citations · 18 references
Natural SciencesNuclear EngineeringPhysicsNuclear PhysicsRadiation PhysicsRadiation ProtectionRadiation Protection PrinciplesRadiation Safety RegulationsHigh-energy Photon DosimetryIonizing Radiation FieldsPhoton EnergyRadiation Field CalibrationRadiation Field CharacterizationSpace Radiation Protection
Three reference radiation fields for the purpose of radiation protection were characterised: (1) radiation field R-F, consisting of photons in the energy range of about 6 and 7 MeV and a small neutron contamination; (2) radiation field R-C, consisting of photons with energies of about 4.4 MeV and neutrons with energies up to 2.65 MeV; (3) radiation field R-CF, consisting of photons in the energy range of about 1 and 7 MeV and neutrons with energies about 1.5 MeV. The radiation fields R-F and R-C have previously been defined in the ISO standard 4037. Their neutron components, however, have never been described accurately in the past. The new radiation field R-CF is proposed for the first time. This radiation field can, e.g., be used to calibrate tissue-equivalent proportional counters instruments for measurements at flight altitudes.
18
MCNP-A General Monte Carlo N-Particle Transport Code
Judith F. Briesmeister · 1993 · 5.1K citations
Radiation protection dosimetry
Jozef Sabol, P.S. Weng · 1995 · 101 citations