Journal of Interventional Cardiology · 1996 · 10 citations · 15 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyTissue EngineeringCoronary AngioplastyCoronary Artery DiseaseCoronary Artery SurgeryPercutaneous Coronary InterventionStent PlacementCompressionCoronary Stent DeploymentExpansionNeointimal Hyperplasia AssessmentSelf-expanding StentsStent Expansion AssessmentVessel Wall HealingVessel Wall Structure
Objectives: To evaluate the expansion ratio of a self‐expanding stem over time, and the chronic effect of stent pressure on the vessel wall . Methods: Self‐expanding stents, developed by Medtronic Inc. (Minneapolis, MN, USA) and the Rouen group (Letac, Cribier, France), were implanted in 21 normal pig coronary arteries. Animals were sacrificed after recatheterization at 1 day (group I, n = 4), I week (group 2, n = 3), 3 weeks (group 3, n = 5), or 8 weeks (group 4, n = 4). Histological morphometry of the vessel medial and neointimal layers was performed. Changes were related to the, stent diameter and. its force on the vessel wall . Results: The stent expansion ratio gradually increased from 73% to 93% after 8 weeks, which implicates that radial force decreased concomitantly from 0.10 N to 0.03 N. Media compression under the rods ranged from 4l%‐66% immediately after stent implantation. The mean compression was unrelated to stent expansion and remained nearly the same (40%‐50%) during follow‐up. Individual media rod compression ranged from 5%‐95%. The neointimal layer on top of the rods increased until the third week after stent implant (neointimal thickness 211 ± 108 μm). The layer significantly decreased at 8 weeks (neointimal thickness 65 ± 9 μm). The cross‐sectional neointimal area increased gradually only at the end of the stent during the 8‐week follow‐up . Conclusions: The self‐expanding stent implanted in normal pig coronary arteries reached a gradual relaxation state 8 weeks after implantation due to the persistent radial force. This radial force induces medial wall compression, which was only positively related to the thickness of the neointimal layer at 3 weeks after implant . (J Interven Cardiol 1996;9:45–52)
15
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Ulrich Sigwart, V. Mirkovitch, F. Joffre et al. · New England Journal of Medicine · 1987 · 1.9K citations
Medicine, Cardiology, Surgery +17
Balloon-expandable intracoronary stents in the adult dog.
Richard A. Schatz, J C Palmaz, Fermin O. Tio et al. · Circulation · 1987 · 375 citations · Full text
Medicine, Cardiology, Surgery +12